A distributor in Germany asked me last month why his oil-filled radiator sales dropped while convection panels climbed. He thought it was price. It wasn't. It was heat-up time. Buyers who want a warm room in ten minutes don't care about the radiator's gentle, silent glow. They care about feeling heat now.
That's the real split between these two product types. Both are electric, both are wall-mounted or portable, and both can carry a CE or UKCA mark. But they behave differently in a room, and your customers will notice. Here's how we build them and where each one actually wins.
How each one moves heat
A convection heater pulls cold air in at the bottom, runs it across a finned element, and pushes warm air out the top. The element is typically 1,500W to 2,000W. It heats the air fast. You feel warmth within a few minutes. The downside is that the air stratifies: hot near the ceiling, cooler at floor level. It also dries the air slightly, which some users complain about.
An oil-filled radiator heats a sealed body of thermal oil, which then radiates and convects heat from its surface. The element is usually 1,000W to 1,500W. It takes 15 to 25 minutes to reach full output. But once it's there, it holds heat after the power cuts, and it stays silent. No fan, no click, no air movement. For a bedroom, that matters.
If your customer is asking about a silent electric heater for a bedroom or a home office, the oil-filled unit is the honest answer. If they want a room warm before guests arrive, convection wins.
The wall-mounted question
Most oil-filled radiators we ship are portable, with castors and a cord. Wall-mounted electric heaters are usually convection panels, because a 1,500W oil unit weighs 15 to 20 kg and needs a serious bracket. We do build wall-mounted oil units, but the MOQ is 200 pcs and the bracket engineering adds cost. For private label electric heater programs, the convection panel is the simpler first SKU: lighter, cheaper to ship, easier to certify.
That said, wall-mounted convection panels are the workhorse for bathrooms and small offices in Europe. A 1,000W panel at 60 cm wide fits above a door or under a window. Pair it with a thermostat and you have a product that sells itself in the €60 to €90 retail band.
Running cost and the energy conversation
Buyers ask about electric heater running cost constantly. The math is simple: a 1,500W heater running at full power for one hour uses 1.5 kWh. At €0.30 per kWh, that's €0.45 per hour. A 1,000W oil radiator uses 1.0 kWh, so €0.30 per hour, but it cycles on and off more once the oil is hot. In a well-insulated room, the oil unit often uses less total energy over a four-hour evening because it holds heat between cycles.
This is where the energy efficient electric heater claim gets tricky. Neither type is magically efficient. Resistance heat is 100% efficient at the element. The savings come from thermostat control and insulation, not from the heater type. If a buyer wants a low wattage electric heater for a small room, a 700W to 1,000W oil unit with a good thermostat is a sensible spec. Don't let anyone tell you a 2,000W fan heater is cheaper to run because it heats faster. It doesn't. It just spends the energy sooner.
Thermostats, WiFi, and the features that actually sell
A best electric heater with thermostat is not about the thermostat alone. It's about hysteresis. A cheap mechanical thermostat swings 3 to 4°C, so the room feels cold then hot. A digital thermostat with 0.5°C hysteresis costs us about $2 more at the factory and changes the user experience completely. For a WiFi smart electric heater, add $6 to $9 for the module and app stack. That's the difference between a €70 retail product and a €110 one.
We ship both. The WiFi version sells better on Amazon in the UK and Germany. The plain digital version sells better to physical retail in Eastern Europe, where buyers want a knob and a price.
Safety and certification notes
Every unit we ship for the EU carries CE and RoHS, and the UK gets UKCA. ERP compliance matters for standby power: keep it under 0.5W or the unit fails the lot. For bathroom units, IP24 is the minimum, and the thermostat must be double-pole. We've seen cheap imports fail on the IP24 gasket after a few hundred cycles. Ask your supplier for the test report, not just the certificate.
For electric heater safety tips you can pass to end users: keep 1 m clearance, never cover the fins, and don't plug a 2,000W unit into a shared extension lead. That last one causes more returns than any manufacturing defect.
Lead times and MOQ reality
Standard MOQ is 200 pcs per model. Lead time is 15 to 45 days depending on whether you need custom packaging, a new mold for the housing, or a private label badge. A stock convection panel with your logo on the carton ships in 15 to 20 days. A new oil-filled radiator body with a custom fin pattern is 35 to 45 days plus tooling. Plan for certification samples to add a week.
The honest takeaway
Oil-filled radiators and convection heaters are not competitors. They solve different problems. If your market wants fast heat and a low shelf price, stock convection. If it wants silence and steady warmth for bedrooms, stock oil-filled. The mistake is trying to sell one as the other. Pick the use case first, then the product. That's how you avoid the inventory problem the German distributor had.
Sourcing this product? Talk to our team.
Tell us your wattage, voltage, MOQ and destination port — we'll reply with tiered pricing and a sample plan within 12 hours.
WhatsApp: +86 574 8888 0000